Mechanical values and environment | |
---|---|
Dimensions | 108 x 22.5 x 114.5 Including screw terminals |
Material | |
Housing | Polyamide |
Ambient temperature | -10 ... +55 °C |
Atmospheric humidity | 10 ... 95 % rH |
Degree of protection | IP20 |
Mounting method | Mounting rail 35mm Acc. to EN 60715 |
Proximity switch | |
Number of axes | 2 |
Connection | 2 Plug-in terminal Terminals not included |
Encoder | |
Number of axes | 1 |
Connection | 1 RJ45 |
Electrical connection ratings | |
Operating voltage DC | |
UB | 24 V DC -20% ... +20% PELV Acc. to EN 60204-1 |
Overvoltage category according to IEC EN 60664-1 | II |
Degree of contamination according to EN 60664-1 | 2 |
Connection cross-section | 0,5 ... 2,5 mm? |
Delay time | 0,0106 ... 0,0546 s depends on the number of slave modules, number of operators, number of OSSD outputs |
Power consumption | max.3 W |
Proximity switch | |
Spacing limits | min.5 % |
Number | 2 |
Frequency | 5 kHz |
Frequency spacing | min.10 Hz |
Limit range | 1 Hz - 4 kHz Configurable |
Type of input | PNP / NPN -3/4-wires |
Encoder | |
Number | 1 |
Frequency | 500 kHz |
Limit range | 1 Hz - 450 kHz Configurable |
Rated surge voltage according to IEC 60664-1 | 4000 |
Rated insulation voltage Ui | 250 |
Interface, bus | |
Encoder | |
Schnittstelle_NT! | SIN/COS |
Reliability values acc. to EN ISO 13849-1 | |
Performance Level | PL e According to ISO 13849-1:2008 / EN 62061:2005 |
Category | 4 According to ISO 13849-1:2008 / EN 62061:2005 |
PFHD | 7.94E-09 1/h Acc. to IEC 61508:2010 |
Mission time | 20 y According to ISO 13849-1:2008 / EN 62061:2005 |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |